#1608 AMG inside CPR fails when time step to large.
Metadata
Property | Value |
---|---|
Reported by | Robert K (robertk@posteo.org) |
Reported at | Apr 7, 2015 09:09 |
Type | Bug Report |
Version | 2.3 |
Operating System | Unspecified / All |
Last edited by | Markus Blatt (markus@dr-blatt.de) |
Last edited at | Jun 11, 2015 07:28 |
Closed by | Markus Blatt (markus@dr-blatt.de) |
Closed at | Jun 11, 2015 07:28 |
Closed in version | Unknown |
Resolution | Fixed |
Comment | This is fixed with commit 05c0a63 in master. Closing as the commit is tagged for the release. |
Description
opm-autodiff example flow throws an istl error when using flow for the SPE9 test case with default parameters except for the preconditioner inside the CPR which is switched to AMG. This error goes away when a smaller time step is chosen.
ISTLError [operator[]:dune-istl/dune/istl/basearray.hh:587]: index 1118 not in compressed array terminate called after throwing an instance of 'Dune::ISTLError